< img height="1" width="1" style="display:none;" alt="" src="https://px.ads.linkedin.com/collect/?pid=5964452&fmt=gif"/>
汉堡
关闭
English
Search
路径
  • 1.Fixed adjustable not running stuck

    The input shaft end of the motor cannot shake the entire row of brackets → check whether the linear actuators have reversed linear actutors → if the linear actuators are installed reversely, the same row of linear actuators will have opposite telescopic directions → need to remove the reversely installed linear actuators and replace them in the same direction.
  • 2.Linear actuator front pull break

    There are cracks or direct disconnection in the forward pull → the limit impact of the ordinary forward pull is 20000N → much higher than the actual working condition → check whether the upper and lower mounting seats of the linear actuators are on the same horizontal plane → if the linear actuator is not on the same level, the linear actuator is subject to lateral force. It will be very large → the upper and lower mounting seats are adjusted to be level
QUICK LINKS

con

COMPONENTS
Linear Actuators
SYSTEMS
Standing Desk Solution
  Add: No.2 Laisheng Road, Provincial High-tech industrial park, Xinchang county, Zhejiang province, China
  Tel: 400-6666-358
 Copyright   2022 Jiecang Sitemap | Privacy Policy